Project Case Study · Karachi Shipyard

ZINGA as a Repair System for Existing Steel Structures

A project-focused look at using a zinc-rich coating to restore and protect existing steelwork, without presenting the work as a new-build galvanising project.

Customer / Project Karachi Shipyard & Engineering Works (KSEW)
Case Study Focus ZINGA as a repair coating on an existing structure
Location Karachi, Pakistan
The Project Approach

Repairing Existing Steel with ZINGA

Using a zinc-rich coating as a practical corrosion-protection option for suitable existing steel structures.

Existing steel structures do not always need to be treated as new-build assets. Where the structure remains in service and full replacement or off-site galvanising is impractical, a properly specified repair coating system offers another maintenance route. In this KSEW case study, the focus is ZINGA as a repair solution, applied to existing steelwork to renew zinc-based corrosion protection. The supplied project photographs show the completed work and its site context. The exact preparation standard, coating thickness and application dates have not been provided, so this page does not assign unsupported technical values.

Work with the Existing Structure

Assess the existing steel and coating condition. Define the repair area and confirm the structure is suitable for recoating.

Prepare the Steel Correctly

Remove contamination, loose coating and corrosion using the preparation method and cleanliness standard in the approved project specification.

Restore Corrosion Protection

Apply ZINGA to the specified film thickness. Inspect the finished coating against the project quality requirements.

Why this repair angle matters: A maintenance coating strategy is especially relevant when steel assets are already installed, difficult to move, or intended to remain in service. The repair specification still needs to account for steel condition, exposure, access, preparation quality and inspection requirements.
Project Photographs

KSEW Project Gallery

Explore the project photographs through the image carousel.

The photographs are presented as project gallery images. They are not labelled as before-and-after stages because no such image-stage identification was supplied.

Repair System Comparison

ZINGA vs. Conventional Repair Coatings

How a zinc-rich repair system differs from a conventional barrier-coating approach on suitable existing steel.

Repair Consideration ZINGA Conventional Epoxy Repair
Zinc-based cathodic protection ✓ ✕
Barrier protection ✓ ✓
Suitable for specified repair work on existing steel ✓ ✓
Requires correct surface preparation ✓ ✓
Can form part of a compatible multi-coat system ✓ ✓
System selection depends on exposure and specification ✓ ✓

This is a general technology comparison, not a verified side-by-side test from the KSEW site. Epoxy formulations vary, and some proprietary systems include zinc-rich primers. Confirm compatibility, surface preparation, film thickness and full system design against current technical data sheets and the project specification.

Repair System Considerations

Where ZINGA Repair Fits

ZINGA is an option for specified maintenance and repair work on suitable existing steel. First assess the substrate and existing coating, then define the repair area and prepare the surface to the required standard. Apply the coating under controlled conditions and verify dry film thickness and finish against the approved project specification. The exact KSEW inspection values should come from the project records.