Zinc-rich formulation
Contains 90% ultra-pure zinc in the dry film for cathodic protection of ferrous metals.
Zinc-rich protection with a bright aluminium finish
ZINGALU is a high-performance, single-component organic zinc-rich coating designed to provide cathodic and barrier protection to ferrous metals. Its dry film contains 90% ultra-pure zinc and 4% aluminium flakes, combining corrosion protection with a bright metallic appearance that matches galvanised surfaces.
Designed for steel protection, maintenance and galvanised-surface repairs.
A high-performance coating combining zinc-based corrosion protection with aluminium's distinctive appearance.
ZINGALU is a one-component organic zinc-rich coating developed to protect ferrous metals. The zinc particles provide cathodic protection, while the aluminium flakes contribute barrier protection and a bright metallic finish.
Its appearance closely matches galvanised surfaces, making ZINGALU suitable for repairing and touching up damaged or aged hot-dip galvanised, ZINGA-coated and other appropriate zinc-coated structures, including zinc-aluminium-magnesium (ZAM) coated surfaces.
The coating can be applied by brush, roller or suitable spray equipment onto a clean, suitably rough substrate. Correct surface preparation, film thickness and application conditions remain essential to the performance of the protective system.
90% zinc in the dry film helps protect ferrous metals against corrosion.
Aluminium flakes contribute barrier protection and the characteristic metallic appearance.
Designed for suitable repairs and touch-ups on aged or damaged galvanised and zinc-coated surfaces.
Combining zinc-rich protection with the appearance and barrier contribution of aluminium.
Contains 90% ultra-pure zinc in the dry film for cathodic protection of ferrous metals.
Aluminium flakes contribute barrier protection and a bright metallic finish that matches galvanised surfaces.
Can be applied by brush, roller, or suitable air-assisted and airless spray equipment.
New ZINGALU layers re-liquidise the previous layer, helping them fuse into a single coating.
For suitable steel structures requiring corrosion protection and a galvanised-style finish.
Repairing and touching up suitable damaged or aged hot-dip galvanised structures.
Suitable repair work on previously ZINGA-coated structures when specified for the project.
Touch-ups on suitable metallised and zinc-coated steel surfaces.
Maintenance of suitable ferrous metal structures where zinc-rich protection is required.
ZINGALU should be applied to a clean, suitably rough substrate. Surface contamination, moisture, environmental conditions and coating thickness can influence the finished coating.
Always follow the latest manufacturer technical data sheet and the approved project specification for preparation, application, drying and inspection.
Read the official ZINGALU TDS ↗Remove contamination and prepare the surface to the specified cleanliness and roughness.
Check ambient temperature, humidity, substrate temperature and dew point.
Use a suitable application method and follow the specified dry-film thickness.
Verify the coating against the project specification and manufacturer's instructions.
Enter the desired thickness, total surface area and loss factor to estimate coating quantity and theoretical volume coverage.
Theoretical estimate only. Practical consumption varies with surface profile, application method and site conditions.
Estimate based on the official TDS volume-solids value.
Key product information summarised from the official ZINGALU Technical Data Sheet V2.0 EN, dated 14 April 2026.
| Product type | Single-component organic zinc-aluminium coating |
|---|---|
| Zinc content in dry film | 90% ±1% by weight |
| Zinc purity | 99.995%, ASTM D520 Type III |
| Aluminium content in dry film | 4% ±1% by weight |
| Wet product density | 2.54 kg/dm³ ±0.06 kg/dm³ |
| Solid content by weight | 80% ±2% |
| Solid content by volume | 63% ±2% |
| Thinner | ZINGASOLV |
| Flash point | 54°C |
| VOC | 530 g/L (215 g/kg) |
| Application methods | Brush, roller, air-assisted spray and airless spray |
| Typical dry-film thickness | 40–150 µm |
| Colour / finish | Grey with aluminium shine |
| Theoretical coverage at 60 µm DFT | 10.5 m²/L or 4.13 m²/kg |
| Theoretical coverage at 110 µm DFT | 5.73 m²/L or 2.26 m²/kg |
| Consumption at 60 µm DFT | 0.24 kg/m² |
| Consumption at 110 µm DFT | 0.44 kg/m² |
| Ambient application temperature | −15°C to +50°C |
| Maximum relative humidity | 95% RH |
| Substrate temperature | At least 3°C above dew point; maximum 60°C |
| Product temperature | +5°C to +30°C |
| Dry-film temperature resistance | −40°C to +120°C, with peaks up to +150°C |
| pH resistance in atmospheric conditions | pH 3.5–12.5 |
| pH resistance in immersion | pH 5.5–9.5 |
| UV resistance | Excellent, according to the manufacturer |
| Packaging | 1 kg, 2 kg, 5 kg, 10 kg and 25 kg options, subject to availability |
| Shelf life | Minimum 3 years in the original unopened package |
Values are based on the manufacturer's published TDS. Consult the current document for complete conditions, recommended systems and limitations.
Access technical specifications and request safety documentation for your project.
Product properties, theoretical coverage, application conditions, packaging and storage guidance.
Open Technical Data Sheet ↗Request the current manufacturer's SDS for hazard identification, safe handling, storage and emergency measures.
Request Safety Data Sheet ↗Do not apply ZINGALU to damp or wet surfaces. Check the substrate temperature against the dew point and follow the manufacturer's application requirements. Read the current product label and Safety Data Sheet before use, and follow suitable PPE, ventilation, storage and disposal procedures.
Contact our team to discuss surface conditions, coating requirements and the right system for your application.